![]() ![]() To create a custom capability and assign roles edit the nf configuration file. Boolean and numeric values (such as the value for splunk-gzip. The custom capability for modular inputs takes the following form:Īfter creating the capability for a modular input, enable it for one or more user roles.Ĭaution: Make sure you assign one or more roles for the capability edit_modinput_ myscheme, otherwise no one can create or edit modular inputs for that scheme. log-opts configuration options in the daemon.json configuration file must be provided as strings. If the custom capability for a modular input is present, the custom capability is applied rather than the default admin_all_objects capability. However, you have the option to create a capability that customizes edit and create permissions for any specific modular input scheme. SplunkTAontap is installed on the machine receiving syslog. This capability also controls reading of other input endpoints.īy default, the admin_all_objects capability controls create and edit permissions for modular inputs. The sourcetype is set to ontap:syslog in the nf file. Read permission for modular input scripts is controlled by the list_inputs capability. Specify permissions for modular input scripts derives from the inputs stanza (for single script instance per input stanza mode) or the scheme name (for single script instance mode). The correct way to configure a persistent queue is to put the persistent queue parameters under each inputs stanza: Because each script produces its own stream, it can have its own persistent queue. In this mode, a script is spawned for each inputs stanza. ![]() There are differences depending on the type of modular input. You configure persistent queues for modular inputs much as you do with other inputs. You can use persistent queues with modular inputs much as you do with TCP, UDP, FIFO, and scripted inputs, as described in Use persistent queues to help prevent data loss. You can configure persistent queues with modular inputs. You cannot modify the interval value for single script instance mode using the endpoint. If interval is set under a specific input stanza, that value is ignored.įor single script instance mode, interval cannot be an endpoint argument, even if it is specified in. ![]() Single script instance per input stanza modeįor single script instance per input stanza mode, each stanza can specify its own interval parameter.įor single script instance mode, Splunk Enterprise reads the interval setting from the scheme default stanza only. The interval parameter is also useful to ensure that a script restarts, even if a previous instance of the script exits unexpectedly.Įntering an empty value for interval results in a script only being executed on start and/or endpoint reload (on edit). The interval parameter specifies when the script restarts to perform the task again. The script performs a specific task and then exits. The interval parameter is useful for a script that performs a task periodically. The interval parameter specifies how long a script waits before it restarts. Use the interval parameter to schedule and monitor scripts. Param2 = p2 #from Configuration stanza Interval parameter The configuration file must contain at least one stanza referencing the input. Host = myHost #from Global default, overridden by Scheme default The file defines the default scheme for the modular input. Here is the spec file for the Amazon S3 example. The stanza definition and their parameters must start at the beginning of the line.A scheme must define at least one parameter.Subsequent definitions (a new scheme stanza) and their parameters are ignored. Modular inputs can only be defined once.Source sourcetype host index disabled interval persistentQueue persistentQueueSize queueSize However, you could specify these to help clarify the usage: Specifying any of the following parameters for your modular inputs has no effect. Adds monitor directory and file inputs to source /var/log./splunk add monitor /var/log/ 2. Some parameters are always implicitly defined.Do not use any of the following as scheme names for your modular inputs:īatch fifo monitor script splunktcp tcp udp Avoid name collision with built-in scheme names.The following regex defines valid identifiers for the scheme name (the name before the ://) and for parameters:.The spec file must be at the following location:.Whichever is entered into the configuration first.Here are some things to keep in mind when writing spec files: To see instructions that work in Unencrypted syslog input. In case of a conflict between a whitelist and a blacklist input setting, which one is used? A. Note Regarding Syslog Over SSL Sending data over encrypted protocols is recommended, when possible. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |